DESOZONE Skid Mounted System
Process Description

Air is drawn from area containing the odors to be removed and washed with basic
ozonated water recycled by the pump.  Sodium hydroxide is added to the recirculated
water by a dosing pump equipped with a pH controller.

DESOZONE System Components

Ozone generator
Air compressor with pre-filter and cooler (customer supplied)
Air filter
Air drier
Cooling water and drain (customer supplied)
Ozone mixing device
Ozone destroyer
Washing system
Contact chamber with packing
Sodium hydroxide addition pump
Sodium hydroxide storage tank
pH control
Blower
Recycle pump
Air to Treat (m3/h)
250
500
1,000
2,500
Air to Treat (SCFM)
156
313
625
1563
O3 Required (g/h)
2
4
8
20
O3 Generator Power (KW)
0.03
0.06
0.12
0.25
Total Power (KW)
0.9
1.2
2.8
3.6
Compressed Air (m3/h)
0.5
1
2
5
Blower power (KW)
0.5
0.75
1.5
2.2
Recycle Pump Flow (m3/h)
1
1
2
5
Recycle Pump Power(KW)
0.3
0.3
1.1
1.1
Coolant Water flow (l/h)
5
10
20
40
Dried Air (m3/h)
0.1
0.1
0.5
1.0
Dimensions W x L x H (m)
1.4 x 2.1 x 2.2
1.4 x 2.1 x 2.2
1.6 x 2.1 x 2.2
1.6 x 2.1 x 2.2
Air to Treat (m3/h)
5,000
10,000
15,000
20,000
Air to Treat (m3/h)
3,125
6,250
9,375
12,500
O3 Required (g/h)
40
80
120
160
O3 Generator Power (KW)
0.6
1.2
1.8
2.4
Total Power (KW)
5.5
8.3
12.2
15.7
Compressed Air (m3/h)
5
10
15
20
Blower power (KW)
2.2
3.3
5.5
7.3
Recycle Pump Flow (m3/h)
10
20
30
40
Recycle Pump Power (KW)
2.2
3.3
4.4
5.5
Coolant Water flow (l/h)
80
160
240
320
Dried Air (m3/h)
2
4
6
8
Dimensions W x L x H (m)
2 x 5.5 x 2.2
2 x 5.5 x 2.2
2.3 x 5.5 x 2.2
2.3 x 5.5 x 2.2
Specifications

Ozone Generator

Dosage                                         8 mg/m3 of air
Design temperature                      30 degrees C
Operating frequency                     820 Hz
Operating voltage, max                 3-9 kV

Cooling water
Temperature in/out                       15/20 degrees C
Operating pressure                       1 bar

Compressor ( EXCLUDED FROM OUR SUPPLY)
Type         Oil Free

Air Filters                 
Coalescent and Carbon

Electrical
380 V, 3 Phase, 60 Hz

Air Drier
Type                                              microporous
Design pressure                            10 bar
Actual Pressure                             7 bar
Design temperature                       30 degrees C
Dew point (at 1 bar)                       -60 degrees C

Sodium Hydroxide
NaOH concentration                      40%
Dosing pump capacity                   0.2 to 2 L/hr Type 200 to 2500,  0.4 to 4 L/hr Type 5000 to 20000
Storage tank                                  50 L Type 200 to 2500, 00 L Type 5000 to 20000

Ozone Mixer and Residual Ozone Destroyer
Power required                               100 W Type 200 to 2500, 500 W Type 5000 to 20000

Scrubber
Type                                                Horizontal
Material                                            PP
Packing                                            Pall/Raschig
Head loss                                        100 mm.w.c.
WxLxH                                              0.5 x 1.4 x 1.6  to 0.8 x 1.6 x 1.6 m, Type 200 to 2500
WxLxH                                             1.3 x 4.5 x 2.2  to 1.7 x 4.5 x 2.2 m, Type 5000 to 20000

Complete with internal drop separator, service piping, valves, bottom tank, drainage, man-hole, level switches.

Blower
Head                                               170 mm.w.c.
Material                                           PP
RPM                                                2850
Noise                                               85 dB at 2 m
Protection                                        IP 55
Transmission                                   Direct

Recycle Pump
Head                                               10 m.w.c.
Material                                           PP
Protection                                        IP 55
RPM                                                2900

Complete with valves, filter and service piping, manometer.

Ambient Conditions
Pressure                                          1000 m bar
Temperature                                    <35 degrees C
Relative Humidity                              <80%