Spartan Environmental Technologies
www.SpartanWaterTreatment.com
DESOZONE Skid Mounted System
Process Description
Air is drawn from area containing the odors to be removed and washed with basic
ozonated water recycled by the pump. Sodium hydroxide is added to the recirculated
water by a dosing pump equipped with a pH controller.
DESOZONE System Components
Ozone generator
Air compressor with pre-filter and cooler (customer supplied)
Air filter
Air drier
Cooling water and drain (customer supplied)
Ozone mixing device
Ozone destroyer
Washing system
Contact chamber with packing
Sodium hydroxide addition pump
Sodium hydroxide storage tank
pH control
Blower
Recycle pump
Specifications
Ozone Generator
Dosage 8 mg/m3 of air
Design temperature 30 degrees C
Operating frequency 820 Hz
Operating voltage, max 3-9 kV
Cooling water
Temperature in/out 15/20 degrees C
Operating pressure 1 bar
Compressor ( EXCLUDED FROM OUR SUPPLY)
Type Oil Free
Air Filters
Coalescent and Carbon
Electrical
380 V, 3 Phase, 60 Hz
Air Drier
Type microporous
Design pressure 10 bar
Actual Pressure 7 bar
Design temperature 30 degrees C
Dew point (at 1 bar) -60 degrees C
Sodium Hydroxide
NaOH concentration 40%
Dosing pump capacity 0.2 to 2 L/hr Type 200 to 2500, 0.4 to 4 L/hr Type 5000 to 20000
Storage tank 50 L Type 200 to 2500, 00 L Type 5000 to 20000
Ozone Mixer and Residual Ozone Destroyer
Power required 100 W Type 200 to 2500, 500 W Type 5000 to 20000
Scrubber
Type Horizontal
Material PP
Packing Pall/Raschig
Head loss 100 mm.w.c.
WxLxH 0.5 x 1.4 x 1.6 to 0.8 x 1.6 x 1.6 m, Type 200 to 2500
WxLxH 1.3 x 4.5 x 2.2 to 1.7 x 4.5 x 2.2 m, Type 5000 to 20000
Complete with internal drop separator, service piping, valves, bottom tank, drainage, man-hole, level switches.
Blower
Head 170 mm.w.c.
Material PP
RPM 2850
Noise 85 dB at 2 m
Protection IP 55
Transmission Direct
Recycle Pump
Head 10 m.w.c.
Material PP
Protection IP 55
RPM 2900
Complete with valves, filter and service piping, manometer.
Ambient Conditions
Pressure 1000 m bar
Temperature <35 degrees C